CGQRL - CARBON DIOXIDE, GAS
- MSDS: CGQRL
- Manufacturer: BOC GROUP INC
- Product Name: CARBON DIOXIDE, GAS
- National Stock Number: 6830-00N014417
Product Identification
Product ID:CARBON DIOXIDE, GAS
MSDS Date:04/01/1995
FSC:6830
NIIN:00N014417
MSDS Number: CGQRL
Responsible Party
MURRAY HILL, NJ 07974
US
Emergency Phone: 800-424-9300 (CHEMTREC)
Info Phone: 908-464-8100
Cage: HO796
Contractor
Telephone: 908-464-8100
Cage: HO796
Ingredients
FERROUS NICKEL ALLOYS ARE SLIGHTLY SUSCEPTIBLE
RTECS: 9999999ZZ
& ELASTOMERS. USE ONLY IN WELL-VENTED AREAS. CO*2
RTECS: 9999999ZZ
CAPS MUST STAY IN PLACE UNLESS CNTNR IS SECURED
RTECS: 9999999ZZ
ROLL CYLS. USE SUITABLE HAND TRUCK FOR CYL MOVEMENT.
RTECS: 9999999ZZ
LOW PRESS (<3000 PSIG) PIPING OR SYSTEMS. DO NOT
RTECS: 9999999ZZ
FROM CYL. USE CHECK VALVE OR TRAP IN DISCHARGE LINE
RTECS: 9999999ZZ
CYLS SHALL NOT BE REFILLED W/OUT EXPRESS WRITTEN
RTECS: 9999999ZZ
WHICH HAS NOT BEEN FILLED BY OWNER OR W/HIS OR HER
RTECS: 9999999ZZ
& FULL LENGTH FACESHIELD .
RTECS: 9999999ZZ
ALL SENSATIONS, EMOTIONAL INSTABILITY & FATG. AS
RTECS: 9999999ZZ
TO CONVLS, COMA, DEATH. OXYGEN DEFICIENCY DURING
RTECS: 9999999ZZ
REMOVE CONTAMD CLTHG; FLUSH
RTECS: 9999999ZZ
SHOULD SEE PATIENT PROMPTLY IF CRYOGENIC BURN RSLTS
RTECS: 9999999ZZ
MD SHOULD SEE PATIENT PROMPTLY
RTECS: 9999999ZZ
PROMPT MED ATTN MANDATORY IN ALL
RTECS: 9999999ZZ
APPRVD SCBA. ASSIST CONSCIOUS PERS TO UNCONTAMD AIR
RTECS: 9999999ZZ
MOST IMPORTANT. MOVE UNCON PERS TO UNCONTMD AREA.
RTECS: 9999999ZZ
FURTHER TREATMENT SHOULD BE SYMPTOMATIC &
RTECS: 9999999ZZ
(52C) STORE CYLS UPRIGHT & FIRMLY
RTECS: 9999999ZZ
EMPTY CYLS. USE FIRST IN-FIRST OUT INVENTORY SYS TO
RTECS: 9999999ZZ
FOR ADDNL STOR RECOMS, CONSULT COMPRESSED GAS
RTECS: 9999999ZZ
CNTNR IN CRYOGENIC LIQ FORM IN ENCLSD SPACE SUCH AS
RTECS: 9999999ZZ
FIRE, EXPLOSION, ASPHYXIATION OR TOXIC EXPOSURE.
RTECS: 9999999ZZ
98.9-99.999
CAS: 124-38-9
RTECS: FF6400000
Fraction By Weight: <99.999%
OSHA PEL 5000 PPM
ACGIH TLV: 5000PPM; 30000 STEL
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYES: CNTCT W/EVAP LIQ MAY CAUSE
FROSTBT/CRYOGENIC BURNS. SKIN: CNTCT W/LIQUEFIED PROD MAY CAUSE
FROTST/CRYOGEINC BURNS UPON EVAP. FROSTBT EFTS ARE CHANGE IN SKIN
COLOR TO GRAY/WHITE, POSS FOLLOWED BY BLISTERS. SKIN MAY BECOME
INFLAMED & PAINFUL. INGEST:UNLIKELY. CNTCT W/EVAP LIQ MAY CAUSE
FROSTBT/ (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:CRYOGENIC BURNS. INHAL: CO*2 IS MOST
POWERFUL CEREBRAL VASODILATOR KNOWN. INHAL LG CONCS CAUSES RAPID
CIRCULATORY INSUFFICIENCY LEADING TO COMA & DEATH. ASPHY IS LIKELY
TO OCCUR BEFORE EFTS O F CO*2 OVEREXP. CHRONIC, HARMFUL EFTS ARE
NOT KNOWN FROM RPTD INHAL OF LOW CONCS. LOW CONCS CAUSE INCRD RESP
& (SUPDAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:EYES: NEVER INTRODUCE OIL/OINTMENT INTO EYES W/OUT MED
ADVICE. IN CASE OF FREEZING/CRYOGENIC BURNS BY RAPIDLY EVAP LIQ. DO
NOT WASH EYES W/HOT OR EVEN TEPID WATER. REMOVE VICTIM FROM SOURCE
OF CONTAM. OPEN EYELIDS WIDE TO ALLOW LIQ TO EVAP. IF PAIN IS
PRESENT, REFER VICTIM TO OPHTHALMOLOGIST FOR FURTHER TREATMENT &
FOLLOW UP. IF VICTIM CANNOT TOLERATE LIGHT, PROTECT EYES W/LIGHT
BANDAGE/ (ING 4)
Fire Fighting
Flash Point:NONE
Lower Limits:NONE
Upper Limits:NONE
Extinguishing Media:MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:USE NIOSH APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE. NONFLAMMABLE.
Accidental Release
Spill Release Procedures:EVACUATE ALL PERS FROM AFFECTED AREA. USE
APPROP PROT EQUIP. IF LEAK IS IN USER'S EQUIP, BE CERTAIN TO PURGE
PIPING W/INERT GAS PRIOR TO ATTEMPTING REPAIRS. IF LEAK IS IN
CNTNR/CNTNR VALVE, CNTCT APPR OP EMER TELEPHONE NUMBER LISTED/CALL
BOC LOCATION.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:PROTECT CYLS FROM PHYSICAL DMG. STORE
IN COOL, DRY, WELL-VENTD AREA AWAY FROM HEAVILY TRAFFICKED AREAS &
EMER EXITS. DO NOT STORE ABOVE 125F (ING 11)
Other Precautions:DRY CO*2 CAN BE HANDLED IN MOST COMMON STRUCTURAL
MATLS. MOIST CO*2 IS GENERALLY CORR BY ITS FORM OF CARBONIC ACID.
FOR APPLICATNS W/MOIST CO*2, 316, 309 & 310 STAINLESS STEELS MAY BE
USED; ALSO HASTE LLOY(R) A,B & C & MONEL(R). (ING 16)
Exposure Controls
Respiratory Protection:NIOSH APPROVED POSITIVE PRESSURE ALIRLINE WITH
FULL-FACE MASK AND EXCAPE BOTTLE OR NIOSH APPROVED SELF-CONTAINED
BREATHING APPARATUS SHOULD BE AVAILABLE FOR EMERGENCY USE.
Ventilation:USE LOC EXHST TO PVNT ACCUM OF HIGH CONCS SO AS TO REDUCE
OXYGEN LEVEL IN AIR TO <19.5% & CO*2 CONC BELOW EXPOS LIMIT.
Protective Gloves:IMPERVIOUS . INSULATED FOR LIQS.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS (ING 24)
Other Protective Equipment:ANSI APPROVED EYE WASH & DELUGE SHOWER .
SAFETY SHOES.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
BP: 109F,43C (CO*2 SUBLIMES). MATL TO AVOID: CARBON DIOXIDE OVER MIX OF
SODIUM PEROXIDE & ALUMINUM OR MAGNESIUM MAY EXPLODE. EFTS OF
OVEREXP: HDCH. EFTS OF OXYGEN DEFICIENCY RSLTG FROM SIMPLE ASPHYXIA
NTS MAY INCL RAPID BRTHG, DIMINISHED MENTAL ALERTNESS, IMPAIRED
MUSC COORDINATION, FAULTY JUDGMENT, DEPRESS OF (ING 2)
Chemical Properties
Boiling Pt:B.P. Text:SUPDAT
Vapor Pres:856 PSIA
Vapor Density:1.53
Solubility in Water:VERY SOLUBLE
Appearance and Odor:A COLORLESS, ODORLESS GAS.
Stability
Stability Indicator/Materials to Avoid:YES
CERTAIN REACTIVE METALS, HYDRIDES, MOIST CESIUM MONOXIDE/LITHIUM
ACETYLENE CARBIDE DIAMMINE MAY IGNITE. PASSING (SUPDAT)
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CARBON MONOXIDE AND OXYGEN WHEN HEATED
ABOVE 3092F (1700C). CARBONIC ACID IS FORMED IN THE PRESENCE OF
MOISTURE.
Disposal
Waste Disposal Methods:DISP MUST BE I/A/W FED, STATE & LOC REGS DO NOT
ATTEMPT TO DISPOSE OF RESIDUAL WASTE/UNUSED QTYS. RETURN IN
SHIPPING CNTNR PROPERLY LABELD, W/ANY VALVE OUTLET PLUGS/CAPS
SECURED & VALVE PROT CAP IN PLACE TO MFR/AUTHORIZED DISTRIBUTORFOR
DISP.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.